Low Bleed

Low-bleed GC and GCMS Columns

There is a rapidly increasing population of benchtop GC/MS instruments in analytical laboratories that analyze a widening range of trace level, higher temperature samples. These samples require increasinglyinert, lower bleed, higher temperature columns. In response to this growing need, Agilent Technologies designed several "ms" columns to chromatograph a broader range of low level samples and generate lower bleed even at higher temperatures.

What makes an Agilent J&W low-bleed column exceptional? Unique polymer chemistry and proprietary surface deactivation, both of which have contributed to columns that adhere to the tightest quality control specifications in the industry for bleed, inertness, selectivity and efficiency. Agilent J&W "ms" columns utilize special surface deactivation and siloxane chemistries which enhance the chromatographic performance of siloxane polymers.

Request Info/Quote

Highlight of the Product Offering

 

DB-1ms

  •  100% Dimethylpolysiloxane
  • Identical selectivity to DB-1
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Improved acid performance compared to standard 100% dimethylpolysiloxane columns
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • 340/360 °C upper temperature limit
  • Excellent general purpose column
  • Bonded and cross-linked
  • Solvent rinsable
 

HP-1ms

  • 100% Dimethylpolysiloxane
  • Identical selectivity to HP-1
  • Non-polar
  • Low bleed characteristics
  • Excellent general purpose column
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
 

VF-1ms

  • Highly inert, non-polar 100% dimethylpolysiloxane phase, low-bleed GC column providing increased
  • Sensitivity over a broad array of applications
  • Ultra low bleed specification of 1 pA at 325 °C (30 m, 0.25 mm, 0.25 µm) for trace analysis with MS
  • QC test results for retention index, efficiency, selectivity and bleed is reported with every column
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with EZ-GRIP to simplify column installation, coupling and operati
 

DB-5ms

  • Phenyl Arylene polymer virtually equivalent to a (5%-Phenyl)-methylpolysiloxane
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Excellent inertness for active compounds
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Exact replacement of HP-5TA
  • Close equivalent to USP Phase G27
 

HP-5ms

  • (5%-Phenyl)-methylpolysiloxane
  • Identical selectivity to HP-5
  • Non-polar
  • Very low bleed characteristics, ideal for GC/MS
  • Excellent inertness for active compounds including acidic and basic compounds
  • Improved signal-to-noise ratio for better sensitivity and mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G27
 

VF-5ms

  • Highly inert 5% phenylmethyl column for increased sensitivity, accuracy and instrument uptime
  • Minimal column bleed improves sensitivity – ultra low bleed specification of 1 pA at 325 °C
  • (30 m x 0.25 mm, 0.25 µm)
  • Slightly higher polarity than VF-1ms, results in improved selectivity for aromatic compounds;
  • selectivity and excellent inertness make these columns applicable for a wide range of semi-polar and even polar compounds
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
 

DB-XlB

  • Exceptionally low bleed
  • Low polarity
  • Extended temperature limit of 340/360 °C
  • Unique selectivity
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses
  • Excellent for pesticides, herbicides, PCBs and PAHs
 

VF-Xms

  • High arylene modified phase for accurate results
  • Isothermal applications up to 340 °C for a broad application range
  • Ideal for confirmational analyses – more polar alternative to 5% phenyl columns
  • Ultra low bleed delivers ultimate sensitivity and signal-to-noise ratio
  • Provides exceptionally high selectivity for semivolatile compounds such as pesticides and delivers high resolution with short analysis time
  • Very unique selectivity for chlorinated compounds
  • QC test results for retention index, efficiency, selectivity and bleed is reported with every column
 

DB-35ms

  • Virtually equivalent to a (35%-phenyl)-methylpolysiloxane
  • Mid-polarity
  • Very low bleed characteristics, ideal for GC/MS
  • Extended temperature limit of 340/360 °C
  • Excellent inertness for active compounds
  • Ideal for confirmational analyses
  • Bonded and cross-linked
  • Solvent rinsable
 

VF-35ms

  • Stabilized arylene-modified equivalent of a 35% phenylmethyl phase
  • Ideal for dual column confirmational analyses
  • Ultra low bleed, highly stable column with a programmable maximum temperature of 360 °C
  • Medium polarity column ideal for trace environmental and chemical analyses
  • 0.15 mm id columns available for high efficiency GC and GC/MS analyses
  • Supplied with an EZ-GRIP to simplify column installation, coupling and operation
 

DB-17ms

  • Virtually equivalent to (50%-phenyl)-methylpolysiloxane
  • 320/340 °C upper temperature limit
  • Very low bleed mid-polarity column, ideal for GC/MS
  • Excellent inertness for active compounds
  • Enhanced mass spectral integrity
  • Bonded and cross-linked
  • Solvent rinsable
  • Excellent choice for CLP pesticides
 

VF-17ms

  • 50% phenyl/50% dimethylpolysiloxane, medium polarity phase
  • Ultra low bleed
  • Proprietary deactivation technology and manufacturing process improves column stability, resulting in improved column-to-column repeatability and column lifetimes
  • Ideal for environmental and clinical methods
  • Ultra low bleed specification at 2 pA at 325 °C (0.25 mm x 30 m, 0.25 µm)
  • Ideal EPA confirmation column for ultimate confidence
  • Bonded and cross-linked
  • Solvent rinsable